Engineering equipment qualification

Engineering Intelligence for Critical Infrastructure.

Vereqta is developing AI-powered software to help engineering teams evaluate complex equipment, identify technical discrepancies, and make more informed procurement decisions.

A 975 kW rating at 8 degrees C ATD, and a 453 kW rating at 4 degrees C ATD. The project requires 500 kW at 4 degrees C ATD, so only the second rating can be compared, and it is 47 kW short. Illustrative sample values.02505007501000246810Approach temperature difference, °C ATDCooling capacity, kWRequired condition: 4°C ATD975 kW at 8°Cdifferent condition47 kW short500 kW required453 kW rated at 4°C
Illustrative sample values, not a real analysis.

The problem

Before a team buys a piece of critical equipment, an engineer has to prove it does what the project requires.

That means reading specifications and manufacturer datasheets side by side. Each manufacturer describes the same characteristics in different formats, and a rating only means something under the conditions it was measured. Finding the mismatches, and the answers that are missing, is slow manual work.

Planned workflow

From specification to a reviewable finding.

  1. 01

    Project Requirements

    Specifications define what the equipment must do.

  2. 02

    Manufacturer Documentation

    Datasheets state what it is rated to do.

  3. 03

    Technical Extraction

    Values and their conditions are identified.

  4. 04

    Condition-Aware Verification

    Ratings are compared only under matching conditions.

  5. 05

    Evidence-Backed Findings

    Each result points to its source.

  6. 06

    Engineering Review

    A qualified engineer decides.

This is the intended workflow. The software is in development, and the only part you can try today is the concept demo, which uses illustrative data.

Initial focus

Liquid cooling for AI data centers.

We are starting with coolant distribution units. Their requirements involve cooling capacity, flow, pressure, temperatures, electrical power, controls and redundancy, which all interact.

Where this could go
Simplified liquid-cooling loop for an AI data centerHeat from server racks is carried by coolant to a coolant distribution unit, which transfers it to facility cooling equipment.Facility coolingChillers · heat exchangersCoolant DistributionUnit (CDU)Heat exchanger · pumps · controlsInitial equipment focusAI compute racksCold plates · manifoldsFacility waterCoolant to racksWarm returnSimplified schematic, not to scale